Fire Protection technology.

Fire Protection technology.

Once you have reviewed the study. guide , please type below the three most important items you took away from the  study. guide  (please submit three items in bulleted, complete sentence format).
UNIT VI STUDY GUIDE
Standpipe and Hose Systems
Course Learning Outcomes for Unit VI
Upon completion of this unit, students should be able to:
3. Explain how the properties of fire influence design and installation criteria.
3.1 Consider the fire dynamics of cooking oil on the design of fire protection.
5. Examine emerging technologies related to fire protection.
5.1 Describe standpipe classifications and components.
5.2 Recognize the possible impairments to standpipe and hose systems.
Required Unit Resources
Chapter 5: Standpipe and Hose Systems
In order to access the following resource, click the link below.
Davis, D. B., Hunt, W., Yoshioka, G., Holler, E., & Kennedy, M. B. (2002, July). Characterization of facility
response planning at facilities that handle, store, or transport animal fats or vegetable oils. Paper
presented at the 2002 Freshwater Spills Symposium, Cleveland, OH.
https://archive.epa.gov/emergencies/content/fss/web/pdf/bdavispaper.pdf
Unit Lesson
Standpipe and Hose Systems
Most of us have seen the movie Die Hard, where the character John McClane pulls the fire hose from the
standpipe cabinet, wraps the hose around his waist, and jumps off the roof of the high-rise just before it
explodes (Gordon & McTiernan, 1998). Several movies have used a standpipe fire hose in realistic and
unrealistic ways. What are standpipe and hose systems? Do individuals really use them to fight fire?
Standpipe and hose systems are designed as a first defense to quickly control fire and, in many cases, may
be the only fire protection available. When high-rise buildings are out of reach of aerial ladders and fire hoses,
firefighters use standpipe systems to engage in firefighting by connecting their hose to the 2.5 inch outlets.
Many fire departments have standard operating procedures of not using the hose system in the cabinet due to
not knowing if the hose has been tested or the condition of the hose. Standpipe systems are a network of
vertical or horizontal pipes and components in large structures and multiple story buildings. In large
structures, there are multiple outlets throughout the area. In high-rise buildings, there could be one per floor or
several depending on the size of the structure. The diameter of the piping can vary and is normally 4–6 inches
in diameter for the riser. There are three different classes of standpipe systems, and the National Fire
Protection Association (NFPA) 14: Standard for the Installation of Standpipe and Hose Systems outlines the
requirements for design and installation (Brakhage et al., 2016). There are five different types of standpipe
systems identified as automatic wet, automatic dry, semiautomatic, manual wet, and manual dry (Brakhage et
al., 2016).
Points to Ponder Scenario
Upon receiving the initial alarm through the pre-action fire alarm control units (FACUs), two workers
previously trained as a part of the fire brigade chose to investigate the alarm. After arriving in the area, the
workers noted the sprinkler system protecting the storage of aerosol cans, large amounts of cooking oil,
plastic bags of coffee products, and cleaning products was at a minimum. Fire was spreading horizontally
FIR 5301, Fire Protection Technology
1
from rack to rack, and the sprinkler system’s pressure was too low to effectively
control
the combustible
UNIT
x STUDY
GUIDE
products. The workers reported the high-pile rack storage, which contained 275-gallon
intermediate bulk
Title
container (IBC) totes with cooking oil inside, had ignited and spread pools of fire running under pallets and
other IBC totes. The workers attempted suppression activities using the single-jacket fire hose from the hose
cabinet. The single-jacket fire hose was a part of the existing structure before the renovation and had several
leaks reducing the pressure. Even with low pressure, when they hit the burning oil, it caused small explosions
and caused the burning oil to disperse even further and spread the fire. The workers were slipping and sliding
as they tried to fight the fire from the large amount of cooking oil mixed with water as it ran out of the loading
dock doors. The fire provided minimal light with large amounts of thick black smoke. The water pressure was
too low to make any headway, forcing the workers to take a defensive position. Once this occurred, fire
quickly spread vertically and horizontally throughout the high-pile storage racks.
During the investigation, it was noted that the lack of water pressure from the Class II automatic wet
standpipe system was due to a reducer that was rusted to the point of partially blocking the opening. In
addition, the single-jacket hose had multiple areas where the jacket was rotten at the folds. In addition,
cooking oil from the fire covered the parking lot, running into the storm water system. The storm water system
was already at maximum height due to flooding, and it overflowed into the canal system connected to a river,
resulting in a massive fish kill. It was also discovered that the facility had 10 IBC totes (275 gallons per tote) of
cooking oil stored in high-pile racks.
In the scenario, what actions and steps should have been taken prior to this event to ensure the check valves
were properly working? Who should have been responsible for the maintenance and checking the singlejacketed fire hose? Were there any hazards with the cooking oil? Was there a need for any type of spill
plans? Are they required to have incident action plans?
Hose Cabinets, Hose, Hose Racks, Reels, and Nozzles
Class I and Class II hose cabinets are normally metal enclosures that are either recessed in the wall or
surface-mounted on the wall. Class III hose cabinets can be made from fiberglass or metal and can be
freestanding, recessed, or surface-mounted on the wall. Hose cabinets can have a rack hose or reeled hose
holding fire protection equipment. Fire hose cabinets come in various sizes and must be large enough to hold
the fire hose, nozzle, and other equipment needed for fighting fires. NFPA 14 states there must be at least 1
inch around the valve handle to ensure the valve can be opened easily. The fire hose cannot be more than
100 feet in length on Class II and Class III and can be either a collapsible or a non-collapsible hose. Class II
systems must operate at pressures so that untrained occupants will be able to manage the hose line.
Cooking Oil Hazards and Flammability
Cooking oils made from animal fats and vegetable oils are hazardous to the environment and are not
considered flammable until the autoignition point is reached. The impact to the environment is similar to
petroleum oil products and is regulated under 40 CFR 12. The physical properties of cooking oil coat
everything that it comes into contact with, changing fire dynamics of all the combustible products such as
cardboard and plastic. In addition, cooking oil in large quantities is toxic and forms toxic products, and cooking
oils from animal fats and vegetables cause hypothermia, dehydration, and diarrhea in coated animals, and it
depletes oxygen in the water, suffocating marine life (Environmental Protection Agency [EPA], 2017).
The EPA has rules that apply to spills from animal fats and vegetable oil. The rules are the Facility Response
Plan (FRP) rule and the Spill Prevention, Control, and Countermeasure (SPCC) rule. These rules require any
facility that handles, stores, or transports cooking oil made from animal fats and vegetable oils have a
response plan that deals with spills of small, medium, and worst-case discharge. The rules also differentiate
between groups of oils based on specific gravity (EPA, 2017). Animal fats and vegetable oils are divided into
groupings of Group A, Group B, and Group C. The response plan must list the quantity of cooking oils and
any discharges that may have occurred. The plan must include training and drills or exercises and how to
handle the hazards.
Buda-Ortins (2010) states that the autoignition of cooking oil is 750 to 815 degrees F (400 to 435 degrees C).
In the scenario, the cooking oil was stored in 275-gallon IBC totes. The IBC totes were exposed to the fire
from other products burning that softened the polyethylene until the totes failed, catastrophically releasing the
cooking oil. According to Quintiere (2017), when heated, polyethylene starts to lose its structure, melting at
FIR 5301, Fire Protection Technology
2
about 250 to 293 degrees F. When the cooking oil covers cardboard boxes and
cardboard
debris,
it allows the
UNIT
x STUDY
GUIDE
cardboard to autoignite at a lower temperature. Cardboard’s ignition temperature
is 800 degrees F (427
Title
degrees C). Quintiere (2017) suggests the autoignition temperature of a substance within a specific
concentration range is the lowest temperature at which it will ignite spontaneously.
Conclusion
Standpipe and hose systems have been used for many things in movies—some realistic and others not.
Standpipe and hose systems were designed to be used in the control and extinguishment of fires in the most
effective way. Firefighters, fire brigades, and occupants have used them throughout history to fight fire.
Standpipe and hose systems are found in large and high-rise structures and must be maintained and tested.
Fire hazards in structures can vary depending on the business and occupancy. In the scenario, the fire
hazards involved several products to include cooking oil stored in IBC totes. For the workers and firefighters
mitigating the warehouse fire, the cooking oil presented several challenges and explosion hazards. It is
important to understand fire dynamics and how fire affects these products in order to provide a safe work
environment and minimize injury to those preforming firefighting tasks.
References
Brakhage, C., Abrams, A., & Fortney, J. (Eds.). (2016). Fire protection, detection, and suppression systems
(5th ed.). Fire Protection Publications.
Buda-Ortins, K. (2010). Auto-ignition of cooking oils.
https://drum.lib.umd.edu/bitstream/handle/1903/11333/Buda_Ortins_ResearchPaper.pdf
Environmental Protection Agency. (2013). Vegetable oils and animal fats. https://www.epa.gov/emergencyresponse/vegetable-oils-and-animal-fats
Gordon, C. (Producer), & McTiernan, J. (Director). (1988). Die hard [Motion picture]. USA: Twentieth Century
Fox.
Quintiere, J. G. (2017). Principles of fire behavior (2nd ed.). CRC Press.
Suggested Unit Resources
In order to access the following resource, click the links below.
You are encouraged to view the videos on standpipes and hose systems as well as the fire hazards of
intermediate bulk container totes.
Fire Equipment Manufacturers’ Association. (2013, November 8). Standpipe rack hose system for fire
protection in commercial buildings [Video]. YouTube

Click here to access the transcript for the video above.
FIR 5301, Fire Protection Technology
3

Order Solution Now

Our Service Charter

1. Professional & Expert Writers: Blackboard Experts only hires the best. Our writers are specially selected and recruited, after which they undergo further training to perfect their skills for specialization purposes. Moreover, our writers are holders of masters and Ph.D. degrees. They have impressive academic records, besides being native English speakers.

2. Top Quality Papers: Our customers are always guaranteed of papers that exceed their expectations. All our writers have +5 years of experience. This implies that all papers are written by individuals who are experts in their fields. In addition, the quality team reviews all the papers before sending them to the customers.

3. Plagiarism-Free Papers: All papers provided by Blackboard Experts are written from scratch. Appropriate referencing and citation of key information are followed. Plagiarism checkers are used by the Quality assurance team and our editors just to double-check that there are no instances of plagiarism.

4. Timely Delivery: Time wasted is equivalent to a failed dedication and commitment. Blackboard Experts is known for timely delivery of any pending customer orders. Customers are well informed of the progress of their papers to ensure they keep track of what the writer is providing before the final draft is sent for grading.

5. Affordable Prices: Our prices are fairly structured to fit in all groups. Any customer willing to place their assignments with us can do so at very affordable prices. In addition, our customers enjoy regular discounts and bonuses.

6. 24/7 Customer Support: At Blackboard Experts, we have put in place a team of experts who answer to all customer inquiries promptly. The best part is the ever-availability of the team. Customers can make inquiries anytime.