Many municipalities have private water systems and fire hydrants that connect to the public water system. Private water systems normally provide water to industrial and commercial structures. Consider the interactions of private/public contractors or engineers with utilities in your city, county, or state. Do you think a private water system would adequately provide water to a fire protection system where you live? Would a public water system adequately provide water to a fire protection system where you live? Is one better than the other? What are your thoughts?
UNIT IV STUDY GUIDE
Water Supply Systems
Course Learning Outcomes for Unit IV
Upon completion of this unit, students should be able to:
1. Recommend appropriate fire protection systems for protecting life and property.
1.1 Discuss the characteristics of fire brigades in the industrial or commercial setting.
6. Evaluate design specifications for fire alarm systems.
6.1 Define the terms pressure, low, and duration as they relate to the movement of water in private
or public water systems.
6.2 Identify and describe the components of a water supply and distribution network.
6.3 Discuss the difference between some public water systems and private water systems.
Required Unit Resources
Chapter 3: Water Supply Systems
Unit Lesson
Water is the most common and most plentiful firefighting extinguishing agent. Understanding the properties of
water is critical in the design of fire protection systems. Designers must know the quantity of water for a given
structure, the pressure required for the fire suppression system, and the friction loss of the system. They must
also know the variables that affect water distribution in both private and public systems. Understanding water
in relationship to temperature is also critical in that it changes the properties and weight of water.
Does a fire suppression system in Florida need more water to absorb the heat of a fire than a fire suppression
system in Michigan? The law of specific heat measures the amount of energy needed to raise its temperature.
Brakhage et al. (2016) explain that it takes 1 joule of heat to 1 pound of water to warm it by 1 degree
Fahrenheit at sea level. HotSpot Energy (n.d.) suggests the average temperature of groundwater in Florida is
72 degrees, and the average in Michigan is 47 degrees. Will the groundwater in Michigan absorb more heat
faster because it is colder and converts to extinguishing properties sooner? Brakhage et al. (2016) suggest
that the extinguishing effect of water is affected by the law of specific heat, law of latent heat of vaporization,
surface area of the water, and specific gravity.
We know that the temperature of water will not increase beyond the boiling point of 212 degrees before it
turns to steam. According to Brakhage et al. (2016), water at an average temperature of 60 degrees needs
152 British thermal units (BTUs) to raise the temperature of water to the boiling point of 212 degrees. If we
use the average groundwater temperature of 72 degrees, you will need 140 BTUs to raise the temperature of
water to the boiling point; if we use the average groundwater temperature of 47 degrees, you need 165 BTUs
to raise water to the point of boiling. The physics of water is needed to understand how much water would be
required to convert water into steam for extinguishing fires. One gallon of water at 60 degrees and 152 BTUs
of heat will convert into steam absorbing 9,358 BTUs of heat. In firefighting, water needs to be applied
effectively to achieve the maximum conversion into steam to absorb the heat from a fire. If you see firefighters
applying water inside a structure and water is running out the door, then it is not being applied effectively to
the seat of the fire. The same is true with fire protection systems. To extinguish a fire, water must be applied
to the seat of the fire in order to be converted into steam.
Water Systems
Have you ever noticed the fluctuation of the water pressure? Sometimes the pressure seems high while it
may seem low at other times. Water demands of a community change continuously during peak usage
FIR 5301, Fire Protection Technology
1
depending on the time of day, week, month, or year. This may leave public water
systems
inadequate
UNIT
x STUDY
GUIDE to
support fire suppression efforts or even supply fire protection systems. Even though
Title the availability of water
seems plentiful in most communities, for firefighting, it can be challenging at times. Fire protection designers
must understand these fluctuations and the properties of water in order to design a proper fire protection
system. This includes flow rate requirements of the sprinkler system and firefighting efforts to mitigate a fire.
The needed flow rate is the number of gallons of water required to extinguish a fire based on the building
type, occupancy, and hazards. The amount of water required for sprinkler systems and firefighting from the
public water system is based on pressure, flow, and duration of operation. Determining these factors is critical
in the design.
Points to Ponder Scenario
During the fire, several workers reported that the sprinkler heads in front of the loading dock doors were
barely operating. They also stated several sprinkler heads directly over the fire, which was started by the
welders, activated. A couple of the workers wearing their normal uniforms (non-fire rated) attempted
suppression activities during the initial fire stage using a hose rack, pre-connected, 1-inch fire hose that was a
part of the existing structure before the renovation. However, the water stream would not reach the fire
because there was no pressure. The workers also stated that a rusty colored water was coming out of the
sprinkler heads and the fire hose line. The public water supply system for the community is ageing, and
deterioration of many of the water mains has caused unreliable water supply during the maximum daily
consumption. The water supply for the multiple sprinkler heads that were activated comes from a 6-inch
private loop off of the secondary feeder from the City of Washington. Just past the loop is a cross-connection
control device connected to the City of Greenville public water supply system, which is a primary feeder. The
City of Greenville’s water main is a 16-inch main reduced down to 6-inches at the cross-connection control
device. The storage tank feeding the industrial area is 200,000 gallons maximum, and recovery time to fill the
tank is 2 hours. The City of Washington is unable to boost the pressure due to the deterioration of the water
system. After the fire and during the investigation, it was found that when the warehouse first opened, there
was a fire brigade due to the distance to the closest fire station. The insurance company required staff to be
trained to fight fire in order to receive a reduction in premiums. Two employees trained as a part of the original
fire brigade that remained after the new owners reorganized the warehouse. However, the new owners did
feel the need for a fire brigade but also felt it increased liability after conducting a risk analysis.
FIR 5301, Fire Protection Technology
2
Was the private loop system effective? Did it provide enough water to the warehouse
to supplyGUIDE
the sprinkler
UNIT x STUDY
system? In order to be effective, water supply systems should be fed from multiple
Title distribution connections
and directions using grids and loops. The least effective water supply system is one that is on a dead-end
such as in the Points to Ponder Scenario. One of the signs that the water system was on a dead-end was the
sediment that accumulated in the water lines from being static and reports of the rusty colored water. After the
sprinkler system activated, the discharge of large amounts of water caused the sediment to break free. In
addition, dead-end mains typically have low pressure due to water being supplied from only one direction.
Brakhage et al. (2016) suggest that loop systems are also referred to as circle systems. Typically, the loop
system supplies water from two different directions. However, as seen in the scenario, the water is supplied to
the private loop from only one direction making it like a dead-end main. Dead-end mains only allow water to
travel in one direction reducing the availability (Brakhage et al., 2016).
Cross-connection control device.
Fire Brigades
Should fire brigades be utilized in fire suppression efforts? Should fire brigades be involved in emergencies
when they occur? National Fire Protection Association (2018) or NFPA 1081: Standard for Facility Fire
Brigade Member Professional Qualifications discusses the magnitude of fire brigades when dealing with fire
emergencies. Fire brigade members should have the knowledge and skills to mitigate fire in an organized
industrial setting providing specific services. Fire brigade members may preform suppression, rescue, or both,
in fire related incidents (NFPA, 2018). The intent is that fire brigade members will be able to control the fire in
the initial fire stage before it reaches the fully developed stages. Fire brigade members utilize fire hoses from
Class I, Class II, and Class III standpipe fire suppression systems; although, Class II systems are less
demanding with better control with lower pressure and volume requirements for individuals to handle
(Brakhage et al., 2016). The standard stresses the importance of individuals in the fire brigade to have proper
training, equipment, and protective clothing.
Conclusion
Water is critical in the extinguishment of fire, and understanding the properties of water makes firefighting
more effective when applied properly at the seat of the fire in order to convert to steam. Water distribution
systems, both private and public, are important in the ability to deliver water to fire protection systems. As
seen in the warehouse fire in the scenario, the effects of firefighting, from a fire brigade or a fire protection
system, can be disastrous when water is not readily available. Not having adequate water for fire suppression
can be life threatening.
FIR 5301, Fire Protection Technology
3
References
UNIT x STUDY GUIDE
Title
Brakhage, C., Abrams, A., & Fortney, J. (Eds.). (2016). Fire protection, detection, and suppression systems
(5th ed.). Fire Protection Publications.
HotSpot Energy. (n.d.). Ground water temperature map – Entering water temperatures [Climatic map].
http://www.hotspotenergy.com/heat-recovery-performance/groundwater-temperature-map.php
National Fire Protection Association. (2018). Standard for facility fire brigade member professional
qualifications (NFPA Standard No. 1081). https://www.nfpa.org/codes-and-standards/all-codes-andstandards/list-of-codes-and-standards/detail?code=1081
Suggested Unit Resources
In order to access the following resources, click the links below.
You are encouraged to read the trends and technologies related to municipal water supply systems with a
focus on interoperability, backup and redundant water supply systems, and critical infrastructure protection.
Hickey, H. E. (2008). Water supply systems and evaluation methods: Volume I: Water supply system
concepts.
https://www.usfa.fema.gov/downloads/pdf/publications/water_supply_systems_volume_i.pdf
Hickey, H. E. (2008). Water supply systems and evaluation methods: Volume II: Water supply evaluation
methods.
https://www.usfa.fema.gov/downloads/pdf/publications/water_supply_systems_volume_ii.pdf
In order to view National Fire Protection Association (NFPA) standards, each student must register for a free
account with the NFPA. Please review the video tutorial on gaining access to the NFPA website and how to
access the NFPA codes there.
Locating and Using NFPA Standards Tutorial: http://libguides.columbiasouthern.edu/nfpastandards
Click here to access the transcript for the tutorial above.
Once you access the codes and standards, review NFPA 1081: Standard for Facility Fire Brigade Member
Professional Qualifications.
National Fire Protection Association. (2018). Standard for facility fire brigade member professional
qualifications (NFPA Standard No. 1081). https://www.nfpa.org/codes-and-standards/all-codes-andstandards/list-of-codes-and-standards/detail?code=1081
FIR 5301, Fire Protection Technology
4

Order Solution Now

Our Service Charter

1. Professional & Expert Writers: Blackboard Experts only hires the best. Our writers are specially selected and recruited, after which they undergo further training to perfect their skills for specialization purposes. Moreover, our writers are holders of masters and Ph.D. degrees. They have impressive academic records, besides being native English speakers.

2. Top Quality Papers: Our customers are always guaranteed of papers that exceed their expectations. All our writers have +5 years of experience. This implies that all papers are written by individuals who are experts in their fields. In addition, the quality team reviews all the papers before sending them to the customers.

3. Plagiarism-Free Papers: All papers provided by Blackboard Experts are written from scratch. Appropriate referencing and citation of key information are followed. Plagiarism checkers are used by the Quality assurance team and our editors just to double-check that there are no instances of plagiarism.

4. Timely Delivery: Time wasted is equivalent to a failed dedication and commitment. Blackboard Experts is known for timely delivery of any pending customer orders. Customers are well informed of the progress of their papers to ensure they keep track of what the writer is providing before the final draft is sent for grading.

5. Affordable Prices: Our prices are fairly structured to fit in all groups. Any customer willing to place their assignments with us can do so at very affordable prices. In addition, our customers enjoy regular discounts and bonuses.

6. 24/7 Customer Support: At Blackboard Experts, we have put in place a team of experts who answer to all customer inquiries promptly. The best part is the ever-availability of the team. Customers can make inquiries anytime.